CGHNP - 14-B SPEEDPRO S/G ENAMELS

  • MSDS: CGHNP
  • Manufacturer: PPG INDUSTRIES INC
  • Product Name: 14-B SPEEDPRO S/G ENAMELS
  • National Stock Number: 8010-00F054695
Product Identification

Product ID:14-B SPEEDPRO S/G ENAMELS
MSDS Date:06/04/1990
FSC:8010
NIIN:00F054695
MSDS Number: CGHNP

Responsible Party
PPG INDUSTRIES INC
260 KAPPA DRIVE
PITTSBURGH, PA 15238-5000
US

Emergency Phone: 800-441-9695/412-482-5555

Info Phone: 800-245-2590/304-943-1300

Cage: DO542

Contractor
PPG INDUSTRIES INC. COATINGS & RESINS GP
9 ALLISON PARK, PA 15101

Telephone: 412-492-5555

Cage: DO542

Ingredients

CLAY (KAOLIN), ALUMINUM SILICATE *97-4*

CAS: 1332-58-7

RTECS: GF1670500

Fraction By Weight: 2-5%

ACGIH TLV: 10 MG/CUM TOTAL DUST


TITANIUM DIOXIDE, TITANIUM OXIDE (SUSPECTED ANIMAL

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 15-20%

OSHA PEL 15 MG/CUM

ACGIH TLV: 10 MG/CUM (DUST)


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 60-65%


FILM FORMERS, RESINS, AND ADDITIVES

Fraction By Weight: 15-20%

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION/INHALATION: HARMFUL. EYES:
IRRITATION. SKIN: SLIGHT IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, REDNESS, ITCHING, BURNING
SENSATION, VISUAL DISTURBANCES, DRYNESS, CRACKING, SWELLING.

First Aid

First Aid:INGESTION: DON'T INDUCE VOMITING. EYES: FLUSH W/PLENTY OF
WATER FOR 15 MINS. SKIN: FLUSH W/PLENTY OF WATER, FOLLOWED BY
WASHING W/SOAP & WATER. INHALATION: REMOVE TO FRESH AIR. APPLY CPR
& OTHER SUPPO RTIVE MEASURES AS REQUIRED. OBTAIN MEDICAL ATTENTION
IN ALL CASES.

Fire Fighting

Flash Point Method:PMCC
Extinguishing Media:CO2, DRY CHEMICAL/UNIVERSAL AQUEOUS FILM FORMING
FOAM.
Fire Fighting Procedures:WATER SPRAY MAY BE INEFFECTIVE. WATER SPRAY
MAY BE USED TO COOL CLOSED CONTAINERS. IF WATER IS USED, FOG
NOZZLES ARE PREFERRABLE. WEAR SCBA.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE/BURST (DUE
TO THE BUILD UP OF STEAM PRESSURE) WHEN EXPOSED TO EXTREME HEAT.

Accidental Release

Spill Release Procedures:PROVIDE MAXIMUM VENTILATION. ONLY PERSONNEL
EQUIPPED W/PROPER EQUIPMENT PROTECTION SHOULD BE PERMITTED IN THE
AREA. REMOVE SOURCES OF IGNITION. TAKE UP MATERIAL W/SAWDUST,
VERMICULITE/OTHER ABSORBENT MATERIAL & PLACE INTO CONTAINERS FOR
DISPOSAL.

Handling

Handling and Storage Precautions:DON'T STORE >120F. PROTECT FROM
FREEZING. STORE LARGE AMOUNTS IN BUILDINGS DESIGNED & PROTECTED FOR
STORAGE OF COMBUSTIBLE LIQUIDS.
Other Precautions:IF MATERIAL IS PART OF A MULTIPLE COMPONENT COATING
SYSTEM, BEFORE BLENDING AS THE RESULTING MIXTURE MAY HAVE HAZARDS
OF ALL OF ITS PARTS.

Exposure Controls

Respiratory Protection:WHERE VENTILATION IS INADEQUATE, USE A SUITABLE
RESPIRATOR.
Ventilation:GENERAL DILUTION/LOCAL EXHAUST IN VOLUME & PATTERN TO KEEP
CONCENTRATIONS BELOW EXPOSURE LIMITS.
Protective Gloves:NITRILE/NEOPRENE/LATEX
Eye Protection:CHEMICAL TYPE SPLASH GOGGLES
Other Protective Equipment:PROTECTIVE CLOTHING.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING & SHOES
BEFORE REUSE.
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:312-474.8F
Vapor Pres:<18
Vapor Density:>1
Spec Gravity:1.1-1.2
Evaporation Rate & Reference:(BUO AC = 100): <36
Solubility in Water:<63%
Appearance and Odor:VISCOUS LIQUID W/CHARACTERISTIC ODOR
Percent Volatiles by Volume:<87

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, STRONG MINERAL ACIDS/STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:TEMPS >120F, FREEZING.
Hazardous Decomposition Products:FUMES, CO.

Disposal

Waste Disposal Methods:EMPTY CONTAINERS SHOULD BE RECYCLED/DISPOSED OF
THROUGH AN APPROVED WASTE FACILITY, IAW/FEDERAL, STATE & LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.